Representative drawn pure copper round rods

Materials Supply / Copper & Copper-Base Alloys

C10100 Oxygen-Free Electronic Copper (OFE)

OFE | UNS C10100 | Cu-OFE CW009A | ASTM F68

C10100 is oxygen-free electronic copper with individually limited impurities. It resists hydrogen embrittlement from internal oxides, making it suitable for vacuum and hydrogen-brazed assemblies.

It is not interchangeable with C10200 (OF) or C11000 (ETP), which have lower purity limits and, for ETP, contain oxygen.

Imagery is illustrative metal product forms, not certified C10100 stock or evidence of Quest stockholding.

Raw & semi-finished materials

Available material forms

CDA lists flat products, rod/bar/shapes, tube and wire. Confirm forms, sizes and availability at enquiry.

  • Sheet, strip and plate
  • Rod, bar and bus bar
  • Tube
  • Wire

Material overview

C10100 Oxygen-Free Electronic Copper (OFE)

The highest-purity commercial copper: ≥99.99% Cu, ≤5 ppm oxygen and 101% IACS minimum conductivity, for vacuum and electronic devices.

  • Conductivity and strength are tied to temper; annealed minimum conductivity is 101% IACS at 20°C.
  • ASTM F68 requires C10100 to B170 Grade 1 chemistry plus electron-device examination requirements.

Designations and specifications

Designations and specifications
Designation / standardScope and qualification
UNS / ENC10100; Cu-OFE, CW009A
ASTM F68Wrought oxygen-free copper for electron devices; additional to the base product specification
ASTM B170 Grade 1Refinery shapes (wire bars, billets, cakes)
ASTM B152 / B187Sheet, strip, plate, rolled bar / bus bar, rod and shapes
EN 13601 / EN 1652 / EN 12163Product families only; individual grade inclusion and current editions not verified

Obtain controlled current standards before ordering.

ASTM F68 — official listing

Specification review

Technical verification requirements

  • Specifications

    Full ASTM B170/F68 chemistry tables and EN grade inclusion not accessed.

    Obtain controlled current standards.

Grade selection

C10100, C10200 and C11000 — distinct coppers

C10100, C10200 and C11000 — distinct coppers
AspectC10100 (OFE)C10200 (OF)C11000 (ETP)
TypeOxygen-free electronicOxygen-freeElectrolytic tough pitch (contains oxygen)
Copper (CDA designation)≥99.99% excl. Ag≥99.95% incl. Ag≥99.90% incl. Ag
Oxygen (CDA designation)≤5 ppm≤10 ppmNo limit in CDA designation; Aurubis strip ≤400 ppm
Individual impurity limits16 elements limitedNone in CDA designationNone in CDA designation
Min. conductivity, annealed, 20°C101% IACS100% IACS100% IACS
Hydrogen embrittlement in reducing atmospheresResistant to oxide-related mechanismResistant to oxide-related mechanismSusceptible

Designation limits are not product-specification acceptance requirements. ETP must not be substituted for OF/OFE where hydrogen brazing, vacuum or reducing-atmosphere service applies.

Copper Development Association — C10100 alloy record

Engineering reference

Technical data

Chemical composition — CDA designation limits
ElementLimit
Copper (excl. Ag)99.99% min
Silver25 ppm max
Sulphur15 ppm max
Iron10 ppm max
Nickel10 ppm max
Oxygen5 ppm max
Lead5 ppm max
Arsenic5 ppm max
Antimony4 ppm max
Phosphorus3 ppm max
Selenium3 ppm max
Tellurium2 ppm max
Tin2 ppm max
Zinc1 ppm max
Bismuth1 ppm max
Cadmium1 ppm max
Manganese0.5 ppm max

CDA designation limits, mass ppm; not independently verified against the full ASTM B170 table.

Copper Development Association — C10100 alloy record

Physical properties and conductivity — C10100
PropertyValueBasis
Electrical conductivity101% IACSAnnealed, 20°C — minimum
Thermal conductivity≈391 W/(m·K) (226 Btu/h·ft·°F)20°C; temper not stated
Density8.94 g/cm³ (0.323 lb/in³)20°C
Mean CTE 20–100°C16.9 × 10⁻⁶/K (9.4 × 10⁻⁶/°F)Temper not stated
Mean CTE 20–200°C17.3 × 10⁻⁶/K (9.6 × 10⁻⁶/°F)Temper not stated
Mean CTE 20–300°C17.6 × 10⁻⁶/K (9.8 × 10⁻⁶/°F)Temper not stated
Elastic modulus (tension)≈117 GPa (17,000 ksi)Temperature and temper not stated
Melting range1083°CCDA

CDA values; metric figures converted from customary units. Cold work reduces conductivity slightly; confirm for the ordered temper. Aurubis strip datasheets report 127 GPa modulus — kept separate.

Copper Development Association — C10100 alloy record

OS050 annealed (0.050 mm grain) — flat, CDA typical

C10100 — OS050 annealed (0.050 mm grain) — flat, CDA typical
PropertyCDA typicalBasis
Tensile strength32 ksi (221 MPa)20°C; flat products, 0.040-in (1.0 mm) section
Yield strength (0.5% extension)10 ksi (69 MPa)Not an Rp0.2 value
Elongation45%Gauge length not stated

CDA typical values for this temper and section only, not specification minima.

Copper Development Association — C10100 alloy record

H02 half hard — flat, CDA typical

C10100 — H02 half hard — flat, CDA typical
PropertyCDA typicalBasis
Tensile strength42 ksi (290 MPa)20°C; flat products, 0.040-in (1.0 mm) section
Yield strength (0.5% extension)36 ksi (248 MPa)Not an Rp0.2 value
Elongation14%Gauge length not stated

CDA typical values for this temper and section only, not specification minima.

Copper Development Association — C10100 alloy record

H04 hard — flat, CDA typical

C10100 — H04 hard — flat, CDA typical
PropertyCDA typicalBasis
Tensile strength50 ksi (345 MPa)20°C; flat products, 0.040-in (1.0 mm) section
Yield strength (0.5% extension)45 ksi (310 MPa)Not an Rp0.2 value
Elongation6%Gauge length not stated

CDA typical values for this temper and section only, not specification minima.

Copper Development Association — C10100 alloy record

Not heat-treatable

These coppers are strengthened only by cold work (H tempers) and softened by annealing (O / OS tempers).

Reducing atmospheres

ETP (C11000) reacts with hydrogen at elevated temperature: hydrogen combines with internal cuprous oxide forming steam and causing embrittlement. OF and OFE resist this oxide-related mechanism.

Oxide test

ASTM B577 is a test method for cuprous oxide in oxygen-free and deoxidised copper; ASTM B170 Grade 1 (C10100) requires ten reverse bends and Grade 2 (C10200) eight after B577 Method D.

No specific annealing temperatures are given here; agree temper with the product specification.

ASTM B577 — official listing

Typical applications

Engineering applications

  • Vacuum seals and vacuum electronic devices
  • Klystrons and microwave tubes
  • Cryogenic shunts
  • High-purity electrical conductors

Subsequent manufacturing

Machining & processing

Brazing and vacuum use

Select OF or OFE for hydrogen brazing, vacuum electronics and reducing atmospheres; ETP is not suitable for these conditions.

Forming

All three cold-form readily; strength rises and conductivity falls slightly with cold work.

Application evidence

Listed applications are source-cited categories, not claims of stock or component approval.

Material certification & testing

Documentation must be agreed for the actual UNS/EN grade, product specification, form, temper and any conductivity or oxygen-content test.

No certificate, conductivity guarantee, approval or grade equivalence is automatic; quotation controls remain disabled.

  • EN 10204 3.1 material certificate, where agreed with the supplier
  • Certificate of Conformity
  • Cast / lot traceability to the producing mill
  • Chemical analysis, including oxygen where specified
  • Electrical conductivity and mechanical test results for the supplied temper, where ordered

Material enquiry

Request a material quotation

C10100 Oxygen-Free Electronic Copper (OFE) supplied to your material form, dimensions and specification.

Material quotation requirements

Attachments — optional

PDF, STEP / STP, text DXF, supported DWG, XLSX, DOCX, JPG, PNG. For legacy DOC / XLS or binary DXF, please export to a supported format.

OR drag and drop files here

6.00 MB remaining of 6 MB

    Attachment limit: 6 MB combined

    If your engineering drawings exceed 6 MB, please submit your enquiry without attachments and we will contact you to arrange a suitable file transfer.

    Files are attached directly to your enquiry email. File validation is not malware scanning.