Materials Supply / Copper & Copper-Base Alloys
C11000 Electrolytic Tough Pitch Copper (ETP)
ETP | UNS C11000 | Cu-ETP CW004A
C11000 contains oxygen as cuprous oxide. It has the same minimum annealed conductivity as C10200 but is susceptible to hydrogen embrittlement when heated in reducing atmospheres.
It must not be substituted for OF or OFE copper in hydrogen brazing, vacuum or reducing-atmosphere service.
Imagery is illustrative metal product forms, not certified C11000 stock or evidence of Quest stockholding.
Raw & semi-finished materials
Available material forms
CDA lists flat products, rod/bar/shapes, forgings (B124), tube and wire. Confirm forms, sizes and availability at enquiry.
- Sheet, strip and plate
- Rod, bar and bus bar
- Tube
- Wire
- Forgings
Material overview
C11000 Electrolytic Tough Pitch Copper (ETP)
The standard electrical copper: ≥99.90% Cu+Ag with a controlled oxygen content and 100% IACS minimum annealed conductivity.
- CDA sets no oxygen maximum for the designation; Aurubis strip limits oxygen to 400 ppm.
- A special low-oxygen Aurubis ETP wire claims hydrogen resistance; this is not generalised to conventional ETP.
Designations and specifications
| Designation / standard | Scope and qualification |
|---|---|
| UNS / EN | C11000; Cu-ETP, CW004A |
| ASTM B152 / B187 / B124 | Flat products / bus bar, rod and shapes / forging rod and bar |
| AMS 4500 | Soft-annealed sheet, strip and plate (CDA); current revision not verified |
| EN 13601 / EN 1652 / EN 12163 | Product families only; grade inclusion not verified |
Copper Development Association — C11000 alloy record
Specification review
Technical verification requirements
Mechanical
CDA does not report H02 yield strength for C11000.
Obtain mill test data where yield is required.
Chemistry
Oxygen content varies by producer; no designation limit.
Specify oxygen limit if relevant.
Grade selection
C10100, C10200 and C11000 — distinct coppers
| Aspect | C10100 (OFE) | C10200 (OF) | C11000 (ETP) |
|---|---|---|---|
| Type | Oxygen-free electronic | Oxygen-free | Electrolytic tough pitch (contains oxygen) |
| Copper (CDA designation) | ≥99.99% excl. Ag | ≥99.95% incl. Ag | ≥99.90% incl. Ag |
| Oxygen (CDA designation) | ≤5 ppm | ≤10 ppm | No limit in CDA designation; Aurubis strip ≤400 ppm |
| Individual impurity limits | 16 elements limited | None in CDA designation | None in CDA designation |
| Min. conductivity, annealed, 20°C | 101% IACS | 100% IACS | 100% IACS |
| Hydrogen embrittlement in reducing atmospheres | Resistant to oxide-related mechanism | Resistant to oxide-related mechanism | Susceptible |
Designation limits are not product-specification acceptance requirements. ETP must not be substituted for OF/OFE where hydrogen brazing, vacuum or reducing-atmosphere service applies.
Copper Development Association — C10100 alloy record
Engineering reference
Technical data
| Element | CDA designation | Aurubis Cu-ETP strip |
|---|---|---|
| Copper + silver | 99.90% min | 99.90% min |
| Oxygen | Not limited in designation | 400 ppm max |
| Bismuth | Not limited | 5 ppm max |
| Lead | Not limited | 50 ppm max |
Aurubis values are producer limits for its strip product, not a universal C11000 oxygen limit.
| Property | Value | Basis |
|---|---|---|
| Electrical conductivity | 100% IACS | Annealed, 20°C — minimum |
| Thermal conductivity | ≈391 W/(m·K) (226 Btu/h·ft·°F) | 20°C; temper not stated |
| Density | 8.91 g/cm³ (0.322 lb/in³) | 20°C |
| Mean CTE 20–100°C | 16.9 × 10⁻⁶/K (9.4 × 10⁻⁶/°F) | Temper not stated |
| Mean CTE 20–200°C | 17.3 × 10⁻⁶/K (9.6 × 10⁻⁶/°F) | Temper not stated |
| Mean CTE 20–300°C | 17.6 × 10⁻⁶/K (9.8 × 10⁻⁶/°F) | Temper not stated |
| Elastic modulus (tension) | ≈117 GPa (17,000 ksi) | Temperature and temper not stated |
| Melting range | 1065–1083°C | CDA |
CDA values; metric figures converted from customary units. Cold work reduces conductivity slightly; confirm for the ordered temper. Aurubis strip datasheets report 127 GPa modulus — kept separate.
Copper Development Association — C11000 alloy record
OS050 annealed (0.050 mm grain) — flat, CDA typical
| Property | CDA typical | Basis |
|---|---|---|
| Tensile strength | 32 ksi (221 MPa) | 20°C; flat products, 0.040-in (1.0 mm) section |
| Yield strength (0.5% extension) | 10 ksi (69 MPa) | Not an Rp0.2 value |
| Elongation | 45% | Gauge length not stated |
CDA typical values for this temper and section only, not specification minima.
Copper Development Association — C11000 alloy record
H02 half hard — flat, CDA typical
| Property | CDA typical | Basis |
|---|---|---|
| Tensile strength | 42 ksi (290 MPa) | 20°C; flat products, 0.040-in (1.0 mm) section |
| Yield strength (0.5% extension) | Not reported | Not an Rp0.2 value |
| Elongation | 14% | Gauge length not stated |
CDA typical values for this temper and section only, not specification minima.
Copper Development Association — C11000 alloy record
H04 hard — flat, CDA typical
| Property | CDA typical | Basis |
|---|---|---|
| Tensile strength | 50 ksi (345 MPa) | 20°C; flat products, 0.040-in (1.0 mm) section |
| Yield strength (0.5% extension) | 45 ksi (310 MPa) | Not an Rp0.2 value |
| Elongation | 6% | Gauge length not stated |
CDA typical values for this temper and section only, not specification minima.
Copper Development Association — C11000 alloy record
Not heat-treatable
These coppers are strengthened only by cold work (H tempers) and softened by annealing (O / OS tempers).
Reducing atmospheres
ETP (C11000) reacts with hydrogen at elevated temperature: hydrogen combines with internal cuprous oxide forming steam and causing embrittlement. OF and OFE resist this oxide-related mechanism.
Oxide test
ASTM B577 is a test method for cuprous oxide in oxygen-free and deoxidised copper; ASTM B170 Grade 1 (C10100) requires ten reverse bends and Grade 2 (C10200) eight after B577 Method D.
No specific annealing temperatures are given here; agree temper with the product specification.
ASTM B577 — official listing
Typical applications
Engineering applications
- General electrical conductors and bus bars
- Transformer and switchgear components
- Electronic components not exposed to reducing atmospheres
Subsequent manufacturing
Machining & processing
Brazing and vacuum use
Select OF or OFE for hydrogen brazing, vacuum electronics and reducing atmospheres; ETP is not suitable for these conditions.
Forming
All three cold-form readily; strength rises and conductivity falls slightly with cold work.
Application evidence
Listed applications are source-cited categories, not claims of stock or component approval.
Material certification & testing
Documentation must be agreed for the actual UNS/EN grade, product specification, form, temper and any conductivity or oxygen-content test.
No certificate, conductivity guarantee, approval or grade equivalence is automatic; quotation controls remain disabled.
- EN 10204 3.1 material certificate, where agreed with the supplier
- Certificate of Conformity
- Cast / lot traceability to the producing mill
- Chemical analysis, including oxygen where specified
- Electrical conductivity and mechanical test results for the supplied temper, where ordered
Material enquiry
Request a material quotation
C11000 Electrolytic Tough Pitch Copper (ETP) supplied to your material form, dimensions and specification.