C10200 Oxygen-Free Copper (OF)

OF | UNS C10200 | Cu-OF CW008A

C10200 is oxygen-free copper. Like OFE it resists the oxide-related hydrogen embrittlement that affects ETP copper, but its designation does not limit individual impurities.

It is not interchangeable with C10100 (OFE) where electron-device purity is specified.

Imagery is illustrative metal product forms, not certified C10200 stock or evidence of Quest stockholding.

Raw & semi-finished materials

Available material forms

CDA lists flat products, rod/bar/shapes, tube and wire. Confirm forms, sizes and availability at enquiry.

  • Sheet, strip and plate
  • Rod, bar and bus bar
  • Tube
  • Wire

Material overview

C10200 Oxygen-Free Copper (OF)

Oxygen-free copper with ≥99.95% Cu+Ag and ≤10 ppm oxygen, for conductors and components brazed or used in reducing atmospheres.

  • Annealed minimum conductivity is 100% IACS at 20°C; CDA tables 101% IACS as a property value — the minimum governs.
  • Aurubis Cu-OF additionally limits Bi and Pb; these are producer requirements.

Designations and specifications

Designations and specifications
Designation / standardScope and qualification
UNS / ENC10200; Cu-OF, CW008A
ASTM B170 Grade 2Refinery shapes
ASTM B152 / B187 / B49Flat products / bus bar, rod and shapes / redraw rod (CDA)
AMS 4501Listed by CDA for light-cold-rolled flat products; current revision not verified
EN 13601 / EN 1652 / EN 12163Product families only; grade inclusion not verified

Copper Development Association — C10200 alloy record

Specification review

Technical verification requirements

  • Chemistry

    No individual impurity limits in CDA designation; Aurubis 99.99/99.95% wording conflict.

    Specify impurity limits and use mill certificate.

Grade selection

C10100, C10200 and C11000 — distinct coppers

C10100, C10200 and C11000 — distinct coppers
AspectC10100 (OFE)C10200 (OF)C11000 (ETP)
TypeOxygen-free electronicOxygen-freeElectrolytic tough pitch (contains oxygen)
Copper (CDA designation)≥99.99% excl. Ag≥99.95% incl. Ag≥99.90% incl. Ag
Oxygen (CDA designation)≤5 ppm≤10 ppmNo limit in CDA designation; Aurubis strip ≤400 ppm
Individual impurity limits16 elements limitedNone in CDA designationNone in CDA designation
Min. conductivity, annealed, 20°C101% IACS100% IACS100% IACS
Hydrogen embrittlement in reducing atmospheresResistant to oxide-related mechanismResistant to oxide-related mechanismSusceptible

Designation limits are not product-specification acceptance requirements. ETP must not be substituted for OF/OFE where hydrogen brazing, vacuum or reducing-atmosphere service applies.

Copper Development Association — C10100 alloy record

Engineering reference

Technical data

Chemical composition
ElementCDA designationAurubis Cu-OF
Copper + silver99.95% min99.95% min
Oxygen10 ppm max10 ppm max
BismuthNot limited5 ppm max
LeadNot limited50 ppm max

OFE impurity limits are not applied to OF. Aurubis narrative states 99.99% Cu while its table states 99.95% — the table and certificate govern.

Physical properties and conductivity — C10200
PropertyValueBasis
Electrical conductivity100% IACSAnnealed, 20°C — minimum
Thermal conductivity≈391 W/(m·K) (226 Btu/h·ft·°F)20°C; temper not stated
Density8.94 g/cm³ (0.323 lb/in³)20°C
Mean CTE 20–100°C16.9 × 10⁻⁶/K (9.4 × 10⁻⁶/°F)Temper not stated
Mean CTE 20–200°C17.3 × 10⁻⁶/K (9.6 × 10⁻⁶/°F)Temper not stated
Mean CTE 20–300°C17.6 × 10⁻⁶/K (9.8 × 10⁻⁶/°F)Temper not stated
Elastic modulus (tension)≈117 GPa (17,000 ksi)Temperature and temper not stated
Melting range1083°CCDA

CDA values; metric figures converted from customary units. Cold work reduces conductivity slightly; confirm for the ordered temper. Aurubis strip datasheets report 127 GPa modulus — kept separate.

Copper Development Association — C10200 alloy record

OS050 annealed (0.050 mm grain) — flat, CDA typical

C10200 — OS050 annealed (0.050 mm grain) — flat, CDA typical
PropertyCDA typicalBasis
Tensile strength32 ksi (221 MPa)20°C; flat products, 0.040-in (1.0 mm) section
Yield strength (0.5% extension)10 ksi (69 MPa)Not an Rp0.2 value
Elongation45%Gauge length not stated

CDA typical values for this temper and section only, not specification minima.

Copper Development Association — C10200 alloy record

H02 half hard — flat, CDA typical

C10200 — H02 half hard — flat, CDA typical
PropertyCDA typicalBasis
Tensile strength42 ksi (290 MPa)20°C; flat products, 0.040-in (1.0 mm) section
Yield strength (0.5% extension)36 ksi (248 MPa)Not an Rp0.2 value
Elongation14%Gauge length not stated

CDA typical values for this temper and section only, not specification minima.

Copper Development Association — C10200 alloy record

H04 hard — flat, CDA typical

C10200 — H04 hard — flat, CDA typical
PropertyCDA typicalBasis
Tensile strength50 ksi (345 MPa)20°C; flat products, 0.040-in (1.0 mm) section
Yield strength (0.5% extension)45 ksi (310 MPa)Not an Rp0.2 value
Elongation6%Gauge length not stated

CDA typical values for this temper and section only, not specification minima.

Copper Development Association — C10200 alloy record

Not heat-treatable

These coppers are strengthened only by cold work (H tempers) and softened by annealing (O / OS tempers).

Reducing atmospheres

ETP (C11000) reacts with hydrogen at elevated temperature: hydrogen combines with internal cuprous oxide forming steam and causing embrittlement. OF and OFE resist this oxide-related mechanism.

Oxide test

ASTM B577 is a test method for cuprous oxide in oxygen-free and deoxidised copper; ASTM B170 Grade 1 (C10100) requires ten reverse bends and Grade 2 (C10200) eight after B577 Method D.

No specific annealing temperatures are given here; agree temper with the product specification.

ASTM B577 — official listing

Typical applications

Engineering applications

  • Electrical conductors and bus bars
  • Hydrogen-brazed and vacuum components
  • Electronic components

Subsequent manufacturing

Machining & processing

Brazing and vacuum use

Select OF or OFE for hydrogen brazing, vacuum electronics and reducing atmospheres; ETP is not suitable for these conditions.

Forming

All three cold-form readily; strength rises and conductivity falls slightly with cold work.

Application evidence

Listed applications are source-cited categories, not claims of stock or component approval.

Material certification & testing

Documentation must be agreed for the actual UNS/EN grade, product specification, form, temper and any conductivity or oxygen-content test.

No certificate, conductivity guarantee, approval or grade equivalence is automatic; quotation controls remain disabled.

  • EN 10204 3.1 material certificate, where agreed with the supplier
  • Certificate of Conformity
  • Cast / lot traceability to the producing mill
  • Chemical analysis, including oxygen where specified
  • Electrical conductivity and mechanical test results for the supplied temper, where ordered

Material enquiry

Request a material quotation

C10200 Oxygen-Free Copper (OF) supplied to your material form, dimensions and specification.

Material quotation requirements

Attachments — optional

PDF, STEP / STP, text DXF, supported DWG, XLSX, DOCX, JPG, PNG. For legacy DOC / XLS or binary DXF, please export to a supported format.

OR drag and drop files here

6.00 MB remaining of 6 MB

    Attachment limit: 6 MB combined

    If your engineering drawings exceed 6 MB, please submit your enquiry without attachments and we will contact you to arrange a suitable file transfer.

    Files are attached directly to your enquiry email. File validation is not malware scanning.